galvanized jacketed pre-insulated steel pipe
Here are some details about galvanized jacketed pre-insulated steel pipe:
Construction: It consists of a steel pipe surrounded by insulation (usually polyurethane foam), which is then encased in a galvanized steel outer jacket.
Galvanized Jacket: The zinc coating on the exterior steel jacket protects it from corrosion. Galvanizing increases durability for underground use where the pipe would be exposed to soil moisture and minerals.
Insulation: Polyurethane foam insulation provides efficient heat retention/transfer prevention. Its closed-cell structure makes it water resistant as well.
Joints: Adjoining sections are joined using insulation joint kits to maintain a continuous thermal break. Special coated fittings allow for connections.
Applications: Commonly used for underground hot and cold water distribution systems, geothermal piping networks, and structural pre-insulated foundations.
Advantages: Pre-insulated pipe provides protection from corrosion, insulation to maintain temperatures, and a factory-applied system that speeds installation.
Sizes: Typically available in diameters from 1-1/4″ to 24″ to accommodate varying flow rates/capacities as needed.
Standards: Must meet ASTM standards for material properties and performance of the steel, insulation and protective jacket.
So in summary, galvanized jacketed pre-insulated steel pipe is a durable, efficient piping solution for temperature-sensitive underground distribution systems. The zinc coating and polyurethane insulation provide protection and performance.
PRODUCT FEATURES
Product name | Galvanized iron jacket insulated pipe |
Length | 6-12m, or by customer’s requirements |
Thickness of Insulation layer | 32-60mm |
Medium teperature | 50°C-120°C, Max: 140°C |
Application | For chilled water tranfer system |
Production Standard | The national standard GB/T29047-2012, CJ/T114-2000, CJ/T155-2001 |
Package | With the plastic or steel end caps on both the pipe ends |
TECHNICAL INDICATORS
Nominal diameter | OD ×Thickness(mm) | Outer protection tube diameter ×Wall thickness(mm) | Insulation thickness(mm) |
25 | 32×3 | 90×2.3 | 29 |
32 | 43×3 | 110×2.5 | 33 |
40 | 48×3 | 110×2.5 | 31 |
50 | 57×3 | 125×2.5 | 34 |
65 | 76×3.5 | 140×3 | 33 |
80 | 89×4 | 160×3.0 | 33 |
100 | 108×4 | 200×3.2 | 36 |
125 | 133×4.5 | 225×3.5 | 46 |
150 | 159×4.5 | 250×3.9 | 45.5 |
200 | 219×6 | 315×4.9 | 48 |
250 | 273×6 | 365×5.6 | 46 |
300 | 325×7 | 420×7 | 47.5 |
350 | 377×7 | 500×7.8 | 61.5 |
400 | 426×7 | 550×8.8 | 62 |
450 | 478×7 | 600×9.8 | 61 |
500 | 529×7 | 655×9.8 | 63 |
600 | 630×8 | 760×11 | 65 |
700 | 720×8 | 850×12 | 65 |
800 | 820×9 | 960×13 | 70 |
900 | 920×10 | 1054×14 | 67 |
1000 | 1020×12 | 1155×14 | 77 |
1200 | 1220×12 | 1380×15 | 80 |
1400 | 1420×14 | 1680×16 | 114 |